Get estimate within 24 hours

Autonomous mobile robots carrying cartons through pallet racking aisles in an automation ready warehouse
Warehouse Automation Support

Automation Ready Building Checklist for Owners and Developers

Know what the robots need before the slab is poured.

Tenants are asking whether a building can take automation, now or five years from now. This automation ready building checklist covers what an integrator checks first: floor flatness, power, clear height, racking and robot layout, and permitting. Use it to spec a new building, qualify an existing one, or plan a retrofit that does not end in a tear out.

01 / Why It Matters

Robots are less forgiving
than forklift drivers.

A driver steers around a dip in the slab, nudges a pallet into a tight bay and keeps working under a light that is out. A shuttle, stacker crane or autonomous mobile robot does none of that. It needs the building to be exactly where the drawings say it is, every shift.

That makes automation readiness a building question first and an equipment question second. The automated pallet racking systems and AMR warehouse solutions tenants are evaluating all depend on the same physical attributes. Get them right during design or before the next lease, and automation becomes an upgrade. Miss them, and it becomes a construction project. This checklist is part of our warehouse automation support.

Ready does not mean robots on day one.

An automation ready warehouse simply removes the obstacles. The tenant decides when, and which system, without fighting the slab, the panel or the permit.

Mobile robots moving between pallet racking aisles in a warehouse planned for automation
Robots follow the layout the building allows. Plan the building for them first.
02 / At a Glance

Six areas decide
whether a building is ready.

01

Floor flatness and slab

Flatness, levelness, joints and load capacity, measured and documented rather than assumed.

02

Power and charging

Service size, panel capacity and charger locations for fleets that may run around the clock.

03

Clear height

Usable height under the lowest obstruction after sprinkler clearance, not the number on the flyer.

04

Racking and robot layout

Column grid, aisle widths, rack tolerances and room for chargers, conveyor and growth.

05

Connectivity and environment

Wireless coverage in every aisle, plus lighting, temperature and dust control.

06

Permitting

High pile storage, fire protection, seismic, electrical and building approvals, sequenced early.

03 / Floor Flatness and Slab

The slab is the
first thing robots test.

Floor flatness is usually measured with F-numbers under ASTM E1155: FF for flatness, the bumps and dips, and FL for levelness, the overall tilt. Many warehouses are poured to a random traffic spec that works well for forklifts. Very narrow aisle trucks, stacker cranes and some guided vehicles often need a tighter, defined traffic tolerance measured along their actual wheel paths.

  • Get a floor survey. Ask for recent FF and FL results, or commission a survey before marketing the building as automation ready.
  • Match the equipment spec. Get the integrator's floor tolerance in writing. Defined traffic aisles may need grinding or a topping to meet it.
  • Check joints and cracks. Small robot wheels feel joints that forklifts roll over. Note joint spacing, fill condition and any spalling.
  • Confirm slab capacity. Taller, denser rack puts heavier concentrated loads on every base plate. Know the slab thickness, reinforcement and soils report.
  • Watch slopes and transitions. Ramps, dock aprons and trench drains limit where robots can travel.
Open warehouse concrete slab ready for a floor flatness survey before automation
Survey the slab before the rack layout is final. Grinding is cheap compared to moving rack.
04 / Power and Charging

Robots run on power
you have to plan for.

Automated fleets charge continuously, often around the clock, and the control systems behind them need clean, reliable power. Utility upgrades, transformers and switchgear can carry long lead times, so power is often the item most likely to delay a go live date.

  • Service and panel capacity. Document available service, spare panel capacity and the path to more if a tenant needs it.
  • Charger zones. Reserve wall or end of aisle space for charging stations on dedicated circuits, protected from traffic.
  • Conduit and pathways. Rough in conduit to likely charger, conveyor and control cabinet locations before rack goes in.
  • Backup and surge protection. Plan how controls, network gear and chargers ride through an outage.
Ask the utility earlyService upgrades can take months, sometimes longer. Start the conversation during design, not after the lease is signed.
Plan lighting at the same timeLED retrofits and controls share the same panels. Coordinate warehouse lighting with charger loads.
Size for the full fleetBuild the backbone for the final phase, even if phase one is only a handful of robots.
05 / Clear Height

Clear height only counts
if you can store in it.

Automation earns its keep by using height a forklift driver cannot safely reach. The height that matters is not the eave or the flyer number. It is the distance from the slab to the lowest obstruction, minus the clearance the sprinkler system requires above the top of storage.

Height to lowest obstruction→Less sprinkler clearance→Less load and beam heights→Usable storage levels
  • Measure to the lowest point. Joists, ducts, lights, sprinkler mains and heaters all count.
  • Respect sprinkler clearance. NFPA 13 sets a minimum clearance between sprinkler deflectors and the top of storage, commonly 18 inches for standard spray and 36 inches for ESFR systems.
  • Run the levels. Divide usable height by load plus beam height to see how many pallet positions each bay really gets.
  • Protect the high bay zone. Keep future obstructions such as new rooftop units or unit heaters out of the racked area.
Tall pallet racking uprights reaching toward the roof joists in a high clear height warehouse
Count from the lowest obstruction, not the roof deck.
06 / Racking and Robot Layout

Lay out the rack
around the robots.

The rack is the structure every automated system stands on. Robots and cranes stop where a driver would simply adjust, so layout and tolerances need to be set with automation in mind, even if the first tenant runs forklifts.

Laid out for forklifts only
  • Aisle widths set by truck turning radius and nothing else.
  • Rack installed to standard tolerances that drivers work around.
  • Columns, drains and doors placed with no thought to robot paths.
  • No space left for chargers, conveyor, guarding or maintenance.
  • Adding automation later means tearing out and re-racking.
Laid out to be automation ready
  • Aisles sized for today's trucks and tomorrow's robots on a clean column grid.
  • Rack engineered to ANSI MH16.1 and installed to tighter plumb, beam elevation and bay spacing tolerances.
  • Travel paths, crossings and pedestrian zones planned around mobile robot safety standards such as ANSI/A3 R15.08.
  • Space reserved for chargers, induction stations, conveyor and future aisles.
  • Automation is added to the system instead of replacing it.

Already have rack in the building? Our warehouse racking team inspects condition and tolerances first. For new installs, selective pallet racking can be engineered to automation tolerances today, so a future retrofit is an upgrade rather than a rebuild.

07 / Connectivity and Environment

The details that keep
robots running.

01

Wireless coverage

A site survey that proves strong signal down every racked aisle, at every height the equipment works.

02

Network backbone

Fiber or cabling to network closets, with room for control servers and redundancy.

03

Lighting

Even, glare free light helps camera and vision guided systems as much as it helps people.

04

Temperature and dust

Batteries, sensors and electronics have operating ranges. Note cold zones, heat and dust sources.

08 / Permitting

Permits decide
when automation goes live.

Dense automated storage is almost always high piled storage. Under the International Fire Code, that generally means combustible storage over 12 feet high, or over 6 feet for high hazard commodities, and it brings a fire review on top of the building permit.

  • High pile storage permit. Commodity classification, storage height, flue spaces and fire department access, reviewed by the fire authority.
  • Fire protection. Confirm the sprinkler system supports the planned height and density, or whether in rack sprinklers are needed.
  • Rack and seismic. Stamped rack drawings and seismic calculations, with heavier anchoring in high seismic markets like California.
  • Electrical. Permits for chargers, new circuits and any service upgrade.
  • Sequence. Start permits during layout, not after the rack ships.

We handle high pile storage permits in house, so the design and the permit move together.

Installers on a scissor lift assembling tall pallet racking for a permitted automation ready layout
09 / How We Review a Building

A readiness review
in six steps.

01

Gather

Drawings, floor survey, sprinkler design and the electrical one line.

02

Walk

On site check of slab, columns, obstructions, power and coverage.

03

Match

Compare the building against the systems the tenant is considering.

04

Lay out

An automation ready rack plan with space reserved for growth.

05

Permit

Map the high pile, fire, seismic and electrical approvals.

06

Report

What is ready, what needs work and what it will take to close the gaps.

10 / Who It's For

Use the checklist
at every stage.

01

Developers

Write slab, power and clear height targets into the base building spec so the space markets as automation ready from day one.

02

Owners

Qualify a vacant or turning building and price the gaps. When upgrades are needed, our warehouse tenant improvement team can scope them.

03

Brokers

Show tenants a plan instead of an empty box with racking plans and enhanced brochures.

Bringing in an integrator? Read about the value of a warehouse automation integrator, and see how autonomous mobile robots fit into existing buildings.

11 / FAQ

Frequently asked
questions.

A warehouse whose slab, power, clear height, layout, connectivity and permits can support automated storage or mobile robots without major rework. It does not need robots installed. It just has no obstacles to adding them.

It depends on the equipment. Many autonomous mobile robots work on a typical warehouse floor if joints and cracks are in good condition, while very narrow aisle trucks and stacker cranes usually need tighter, defined traffic tolerances along their wheel paths. Get the specification from the equipment supplier and compare it to a current floor survey.

There is no single minimum. More usable height generally means more pallet positions per square foot, which improves payback. What matters is the height below the lowest obstruction after the required sprinkler clearance.

They need charging stations on dedicated circuits, panel capacity for the full fleet and reliable power for network and control equipment. Large fleets and automated storage systems may require a service upgrade, which can take months.

Usually, yes. Dense automated storage is typically high piled combustible storage, which the fire authority reviews for commodity, height, sprinklers and access. SOURCE Racks handles high pile permits in house.

Often, yes. Floors can be ground or topped, power can be added, and rack can be inspected or replaced to tighter tolerances. A readiness review shows which upgrades are needed and in what order.

Owners and developers own the building items like slab, power and clear height. Tenants and integrators own the equipment choice. A racking partner that handles layout and permits connects the two.

Robotic shuttles moving cartons along rails between tall automated storage racks
Plan for What's Next

Find out if your building is automation ready.